research ultrasound platform vantage-128 Search Results


86
Verasonics Inc verasonics vantage 128 system
a Schematic of the wire imaging setup using the Verasonics <t>Vantage</t> <t>128</t> system. b Wire image obtained under conventional and pre-snapback modes. c Comparison of imaging intensity at a depth of 7 mm in conventional and pre-snapback modes. d Imaging intensity as a function of depth for conventional and pre-snapback modes
Verasonics Vantage 128 System, supplied by Verasonics Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/research+ultrasound+platform+vantage-128/128+system+vantage+verasonics/pmc13190714-149-20-20
Average 86 stars, based on 1 article reviews
verasonics vantage 128 system - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Verasonics Inc research ultrasound system
<t>Ultrasound</t> beams that are used within this study. ( A ) Conventional focused beam. ( B ) Weakly focused beam where the focus is placed outside the field of view. ( C ) Weakly diverging beam with a virtual focus far above the transducer. ( D ) Diverging wave with a virtual focus close to the transducer.
Research Ultrasound System, supplied by Verasonics Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/research+ultrasound+platform+vantage-128/research+system+ultrasound/pmc13193581-62-6-9
Average 86 stars, based on 1 article reviews
research ultrasound system - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


a Schematic of the wire imaging setup using the Verasonics Vantage 128 system. b Wire image obtained under conventional and pre-snapback modes. c Comparison of imaging intensity at a depth of 7 mm in conventional and pre-snapback modes. d Imaging intensity as a function of depth for conventional and pre-snapback modes

Journal: Microsystems & Nanoengineering

Article Title: Pre-snapback mode operation of CMUT for enhanced acoustic performance

doi: 10.1038/s41378-026-01228-x

Figure Lengend Snippet: a Schematic of the wire imaging setup using the Verasonics Vantage 128 system. b Wire image obtained under conventional and pre-snapback modes. c Comparison of imaging intensity at a depth of 7 mm in conventional and pre-snapback modes. d Imaging intensity as a function of depth for conventional and pre-snapback modes

Article Snippet: Fig. 5 Comparison of acoustic performance of conventional and pre-snapback modes. a Schematic of the wire imaging setup using the Verasonics Vantage 128 system. b Wire image obtained under conventional and pre-snapback modes. c Comparison of imaging intensity at a depth of 7 mm in conventional and pre-snapback modes. d Imaging intensity as a function of depth for conventional and pre-snapback modes Additionally, the high loop gain of the pre-snapback mode enabled detection of deeper signals, with a 5.1-fold stronger signal observed at a depth of 45 mm, allowing for distinct visual identification (Fig. ).

Techniques: Imaging, Comparison

Ultrasound beams that are used within this study. ( A ) Conventional focused beam. ( B ) Weakly focused beam where the focus is placed outside the field of view. ( C ) Weakly diverging beam with a virtual focus far above the transducer. ( D ) Diverging wave with a virtual focus close to the transducer.

Journal: European Heart Journal. Imaging Methods and Practice

Article Title: Study design and rationale of the Visualizing Subclinical Myocardial Changes with Shear Wave Elastography in Dilated Cardiomyopathy (VISUALIZE-DCM) trial

doi: 10.1093/ehjimp/qyag071

Figure Lengend Snippet: Ultrasound beams that are used within this study. ( A ) Conventional focused beam. ( B ) Weakly focused beam where the focus is placed outside the field of view. ( C ) Weakly diverging beam with a virtual focus far above the transducer. ( D ) Diverging wave with a virtual focus close to the transducer.

Article Snippet: Ultrasound data is acquired using a research ultrasound system (Verasonics Vantage 128, Kirkland, USA) with a commercial Philips S5-1 transducer (Philips Healthcare, Bothell, USA).

Techniques: